The two 1.6 TB PCIe flashcards included with the OnMetal I/O flavor come unformatted. Use the following steps to configure your flashcards for use as a data disk.
Determine what devices are the PCIe block devices.
Note: Find the high performance PCIe cards by running
lsblk -oNAME, MODEL
and looking for devices listed with modelNWD-BLP*
orXP6302*
.Apply best SSD settings for each devices (sub DEVICENAME with name identified in step 1).
echo noop | sudo tee /sys/block/DEVICENAME/queue/scheduler echo 4096 | sudo tee /sys/block/DEVICENAME/queue/nr_requests echo 1024 | sudo tee /sys/block/DEVICENAME/queue/max_sectors_kb echo 1 | sudo tee /sys/block/DEVICENAME/queue/nomerges echo 512 | sudo tee /sys/block/DEVICENAME/device/queue_depth
(Optional) Partition the created Redundant Array of Independent Disks (RAID) device if you prefer, or you can create a file system (FS) directly.
Create an ext4 FS on it.
mkfs.ext4 /dev/md0